Model NO.: YJV YJLV YJV22 YJLV22 YJV32 YJLV32
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: YJV
Brand: Jinshui
Nominal Sectional Area: 1.5 - 1000mm2
Number of Core: 1 - 5 Cores
Amour: Swa or Sta
Rate Voltage: 1 - 35 Kv
Experience: 20 Years
Trademark: Jinshui
Transport Package: All Wooden Drum or Iron-Wooden Drum, All Iron Drum
Specification: YJV YJLV YJV22 YJLV22 YJV32 YJLV32
Origin: China
HS Code: 8544492100
Model NO.: YJV YJLV YJV22 YJLV22 YJV32 YJLV32
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: YJV
Brand: Jinshui
Nominal Sectional Area: 1.5 - 1000mm2
Number of Core: 1 - 5 Cores
Amour: Swa or Sta
Rate Voltage: 1 - 35 Kv
Experience: 20 Years
Trademark: Jinshui
Transport Package: All Wooden Drum or Iron-Wooden Drum, All Iron Drum
Specification: YJV YJLV YJV22 YJLV22 YJV32 YJLV32
Origin: China
HS Code: 8544492100
Application:It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90° C. In short circuit, conductor highest temperature should be not more than 250° C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. Of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90° C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250° C.
4. D. C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0° C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test: .
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Type | Description | Number of cores | Nominal cross section of conductor |
YJV32 | CU/XLPE/SWA/PVC Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
YJLV32 | AL/XLPE/SWA/PVC Power Cable | ||
YJV72 | CU/XLPE/Non-magnetic SWA or AWA/PVC Power Cable | 1 | 1.5~1000mm 2 |
YJLV72 | AL/XLPE/Non-magnetic SWA or AWA/PVC Power Cable | ||
YJV33 | CU/XLPE/SWA/PE Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
YJLV33 | AL/XLPE/SWA/PE Power Cable | ||
Z-YJV32 | CU/XLPE/SWA Flame-retardant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
Z-YJLV32 | AL/XLPE/SWA Flame-retardant Power Cable | ||
WDZ-YJY33 | CU/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
WDZ-YJLY33 | AL/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable | ||
N-YJV32 | CU/XLPE/SWA Fire-resistant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90° C. In short circuit, conductor highest temperature should be not more than 250° C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. Of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90° C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250° C.
4. D. C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0° C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test: .
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Type | Description | Number of cores | Nominal cross section of conductor |
YJV32 | CU/XLPE/SWA/PVC Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
YJLV32 | AL/XLPE/SWA/PVC Power Cable | ||
YJV72 | CU/XLPE/Non-magnetic SWA or AWA/PVC Power Cable | 1 | 1.5~1000mm 2 |
YJLV72 | AL/XLPE/Non-magnetic SWA or AWA/PVC Power Cable | ||
YJV33 | CU/XLPE/SWA/PE Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
YJLV33 | AL/XLPE/SWA/PE Power Cable | ||
Z-YJV32 | CU/XLPE/SWA Flame-retardant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
Z-YJLV32 | AL/XLPE/SWA Flame-retardant Power Cable | ||
WDZ-YJY33 | CU/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
WDZ-YJLY33 | AL/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable | ||
N-YJV32 | CU/XLPE/SWA Fire-resistant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm 2 |
LED Spot Light, Cool White LED Spot Light,Aluminum LED Spot Light,1W LED Spot Light
LED Downlight Co., Ltd. , http://www.satisledlight.com