XGN-40.5 C-GISGas Insulation Cabinet Metal-Clad Switchgear

Model NO.: DXG-40.5
Rated Current: 630 a
Rated Short Time Continual Time: 4 S
Shell Protection Grade: IP56
Application Range: Substation, Building
Brand: Tianan
Trademark: Tianan Electric
Transport Package: Standard Export Packing
Specification: IEC60076-1, IEC60076-2, IEC60076-5
Origin: Xiangshan Zhejiang P. R China
HS Code: 8537209000

GIS-Gas Insulated Switchgear
NINGBO TIANAN (GROUP) CO., LTD.

General
The GIS is suitable for power plant, substation, combined substation and electric power system, which is three phase indoor AC single busbar and sectioning single busbar with 50Hz, 35kV rated voltage, used to control, accept and distribute electric power.
Standard
>>IEC 60265-1, IEC 6227-1, EC 62271-100, -102, -105, -200 and IEC 60529 
Available modules
>>C:  Cable Switch
>>De:  Direct Cable Connection with earthing
>>D:   Direct Cable Connection
>>F:    Switch-Fuse Disconnector
>>V:   Vacuum Circuit breaker
>>Be:  Busbar earthing
>>Sl:   Busbar Sectionalizer, load break switch
>>Sv:  Busbar Sectionalizer, vacuum circuit breaker
>>CB: Circuit-breaker module
>>M:   Metering Module
>>Mt:  Metering tariff module
Functional design
1. Reliable
  Each compartment is monitored individually & has its own pressure relief device.
2. Safety
 The primary side components are hermetically enclosed, gas filled compartment and thus insensitive
  to atmosphere, dirt &dust.
3. Space saving
  Smaller foot prints All operations on the switchgear front.
4. Economically efficient
  Reduced space & surface area requirement. Long service life Maintenance free Gas compartment.
Specifications
 
No. Item unit Parameter 
1 Rated voltage KV 12
2 Main busbar rated current A 630
3 Rated current A 630
4 Rated frequency  HZ 50
5 Rated short-time withstand current KA 20
6 Rated short time continual time S 4
7 Rated peak withstand current KA 50/125
8 Rated short-circuit making current KA 50
9 Rated active load breaking current A 630
10 Rated closed loop breaking current A 630
11 Rated cable-charging breaking current  A 10
12 The earthing switch rated 
short-time resistance current 
KA 20
13 Grounding switch rated 
short circuit duration
S 4
14 Grounding switch rated 
peak withstand current
KA 50
15 Rating insulation level 1min Power 
frequency withstand 
voltage
KV (phase to phase/ phase-to-ground) 42;
(isolating distance) 48
lightning impulse 
withstand voltage
(peak value)
KV (phase to phase/ phase-to-ground) 75;
(phase to phase/ phase-to-ground) 85
16 major loop resistance   ≤400
17 mechanical life Load switch time 5000
Earthing switch  time 2000
18 subsidiary loop 1min Power 
frequency withstand voltage 
KV 2
19 SF6 Rated Gas pressure 
(20ºC gauge pressure)
Mpa 0.04
20 SF6 Gas annual Leakage rate   1%
21 Protection grade    IP4X
 
XGN-40.5 C-GISGas Insulation Cabinet Metal-Clad Switchgear
XGN-40.5 C-GISGas Insulation Cabinet Metal-Clad Switchgear
XGN-40.5 C-GISGas Insulation Cabinet Metal-Clad Switchgear

6000 - 10000 Puffs (included)

Shenzhen Zpal Technology Co.,Ltd , https://www.zpalvapes.com

This entry was posted in on